(NAR) VOL. 5 NO. 2/APRIL-JUNE 1994
1. Service Contract | ||
a) Petroleum | P0.30/hec | |
b) Uranium | 0.30/hec | |
2. Geophysical Contract | ||
a) Petroleum | 0.30/hec. | |
3. Exploration Permit | ||
a) Petroleum | 20,000.00 | |
b) Coal | P100/block | |
c) Uranium | P100/block |
1) Screening tests | ||
c. Pyrolysis by Rock - | ||
Eval V | P350.00 | |
2) Detailed tests | ||
Gas Chromatography - Mass | ||
Spectrometry of Saturate or | ||
Aromatic Fractions (from | ||
B.2.3rd paragraph) - | P1,500.00 |
Chloride (Cl) > 1,000 ppm 140.00
Chloride (Cl) < 1,000 ppm 60.00
Bicarbonate (HCO3) ) Carbonate (CO3) ) 100.00 Carbon Dioxide (CO2) )
For inclusion of additional clause
1. Fuel Testing Heating Value without sulfur/D-240 220.00with sulfur/D-240/129 595.005. Instrument Calibration-Basic Charges B. Pressure Deadweight tester 400.00C. Electrical AC Power Walt meters 100.00Resistance Resistance decade >0.01% accuracy 250.00 Power Supplies DC type 120.00 XY recorder 250.00 Industrial Signal Conditioners Temperature transmitter 60.00 Pressure transmitter up to 30 psi 150.00 Pressure transmitter up 30-1,600 psi) 400.00 Diff. Press. Cells/ transmitter 150.00 Pneumatic to V/I signal converter 150.00 V/1 signal to pneumatic signal converter 150.00 V to I converter (I to V converter) 60.00 Control valves 140.00
f. Energy labelling 1 lot = 20 energy labels for imported refrigerators 85/lot
1. Fuel Testing — discounted price/batch Maximum no. Discounted of addl. Sple/Price Batch (Batch) Ash (liquid Fuels)/D-482 1 340.00 Ash (Agriwastes)/D-3174 3 95.00 (Coal/Coke)/D-3174 3 95.00 Ash, Sulfated/D-874 1 370.00 Cloud Point above 32 C/D-2500 3 60.00 10 C to 32 C/D-2500 -2 C to 10 4 60.00 C/D-2500 4 140.00 below -2 C/D-2500 4 115.00 Heating Value/D-240/1552 1 460.00 Insolubles, Pentane/D-893 1 460.00 Toluene/D-893 1 685.00 Moisture (Solid Fuels)/ D-3173 3 55.00 Pour Point above 32C/D-97 3 60.00 10 C to 32 C/D-97 4 60.00 -2 C to 10 C/D-97 4 140.00 below -2 C C/D-97 4 155.00 Proximate Analysis/ 3 160.00 D-3172 Sulfur (Bomb washing)/D-129 1 210.00 (Iodometry)/D-1552 1 200.00 Total Acid No./D-974 3 205.00 Viscosity, Kinematic/D-445 1 145.00 Index/D-2270 1 290.00 Volatile Matter/D-3175 3 55.00 Water & Sediment (BS & W)/ D-1796 1 95.00 2. Water Testing — discounted price/batch Maximum no
of Addl.
Sple/Batch Discounted
Price
(Batch) Acidity 5 95.00 Alkalinity, Phenolphthalein 5 35.00 Alkalinity, total 5 125.00 Ammonia, Nitrogen 2 65.00 Chloride 5 170.00 Color, True 2 35.00 Dissolved Oxygen (Oximeter) 2 60.00 Hardness, Calcium 5 110.00 Hardness, Total 5 160.00 Hydrazine 2 65.00 Iron, Ferrous 2 60.00 Iron, Total 2 95.00 Nitrate 2 115.00 pH 5 35.00 Phosphate 2 135.00 Silica, High Range 2 135.00 Silica, Low range 2 105.00 Sulfate 2 125.00 Sulfite 5 65.00 Total Dissolved Solids Gravimetric Method 2 225.00 Total Suspended Solids 2 140.00 Total Solids 2 155.00 Turbidity 2 35.00 5. Instrument Calibration-Basic Charges Standards Bridge/Comparator/Divider 3,400.00 Power, AC 1,900.00 Pressure 800.00 PRT/Thermocouple 880.00 Standard Resistor 1,700.00 Voltage, AC 1,700.00 Voltage, DC 2,250.00 To correct typographical errors noted 1. Fuel Testing Heating Valve - should be Heating Value Ash (Agrivates) - should be Ash Agriwastes) 2. Water Testing Dissolved Oxygen - should be Dissolved (Oimeter) Oxygen (Oximeter)
Philippine Medium Term
Energy Plan Manual P250.00